Air Conditioning Split or AC Split is one of the air conditioning system that works by using a vapor compression system. The vapor compression system is one of the most cycles used for mechanical refrigeration systems, while the vapor refrigerant will be compressed by the compressor as the main component in addition to other components such as condensers, expansion valves and evaporators. This research focuses on AC Split Coefficient of Performance (COP) with Comparison of Refrigerants R410a and R32 with variations speed based on the Evaporator Fan speed. This analysis method uses two AC Split each capacity is 1PK with two different of refrigerants R32 and R410a, as well as varying in Low, Medium and High-level speed with air flow velocity in each mode respectively 1.2 m/s, 1.5 m/s and 1.9 m/s. From the result that COP on R410a refrigerant is 8.13 and COP on R32 refrigerant is 5.3. And also, the efficiency of R410a is 72.8% and R32 is 70.67%. So, AC Split with refrigerant R410a has better COP compared with AC Split with refrigerant R32.

 

Keywords: COP, AC Split, Refrigerants, R410a, R32, Efficiency


Full Text:

Article 2(2)(2019)

References


Elatar, Ahmed., 2018. Evaluation of flammable volume in the case of a catastrophic leak of R-32 from a rooftop unit. International Jurnal of Refrigeration, Volume 91, pp. 39-45

Pita,Edward G. 2002.Air Conditioning Principles and Systems. Ohio.Prentice Hill

Kusnandar,Gusniawan, 2016. Kajian Eksperimental Heat Exchaner Pada Heat Pump Menggunakan Refrijeran Hidrokarbon. Jurnal Mechanical Unila. Volume 7. Nomor 1. Pp. 9-14

Kusnandar,Fajar Sentosa,2016.Analisa Performansi Heat Pump Menggunakan Counter Flow Heat Exchangers. Jurnal Teknologi Terapan (JTT) Polindra. Volume 2 Nomor 2.

Kusnandar, 2018. Analisa Performansi Mesin Pengkondisi Udara Menggunakan Refrigerant R32. Seminar Nasional Penelitian Pengabdian Masyarakat, Universitas Bangka Belitung.

Kusnandar, Yudhy Kurniawan, Yusup Nur Rohmat, 2018. Analisa Panas Kondensor Pada AC Split Menggunakan refrigerant R32, Seminar Nasional Keteknikan, Universitas Khoirun, Ternate.




DOI: http://dx.doi.org/10.36767%2Fturbulen.v2i2.553

Refbacks

  • There are currently no refbacks.


Creative Commons License
This work is licensed under a Creative Commons Attribution 3.0 License.

Published by Mechanical Engineering Study Program, Faculty of Engineering, Universitas Tridinanti Palembang

Contact Us:

TURBULEN: Jurnal Teknik Mesin

Phone/WhatsApp/sms : +62821-7853-3625 or +62852-6805-4099

email:jurnal.turbulen@univ-tridinanti.ac.id

e-ISSN: 2656-0186